Table 7-2 Apparent power
Parameter Description Value Range
Maximum apparent
power (kVA)
Species the output
upper threshold for the
maximum apparent
power to adapt to the
capacity requirements of
standard and customized
inverters.
[Maximum active power,
S
max
]
Maximum active power
(kW)
Species the output
upper threshold for the
maximum active power
to adapt to dierent
market requirements.
[0.1, P
max
]
The lower threshold for the maximum apparent power is the maximum active power. To
lower the maximum apparent power, lower the maximum active power rst.
7.2.1.3 Battery Control
Prerequisites
The screenshots in this chapter are taken in the SUN2000 3.2.00.011 App. The App
is being updated. The actual screens may vary.
Function
When the inverter connects to a battery, add the battery and set battery
parameters.
Adding a Battery
To add a battery, choose Maintenance > Subdevice management on the home
screen.
Figure 7-13 Adding a battery
SUN2000-(3KTL-10KTL)-M1 Series
User Manual 7 Man-Machine Interaction