Figure 7-15 Setting capacity control parameters
Parameter Description Range
Capacity control 1. Before enabling Capacity
control, set Charge from
grid to Enable.
2. Before disabling Charge
from grid, set Capacity
control to Disable.
● Disable
● Active capacity limit
Backup power SOC
for peak shaving
(%)
The value of this parameter
aects the peak shaving
capability. A larger value
indicates stronger peak shaving
capability.
[0.0, 100.0]
Backup power SOC for
peak shaving > Backup
power SOC (when
BackUp is enabled) >
End-of-discharge SOC
Start date ● Set the peak power range
based on the start time and
end time. The peak power is
congured based on
electricity prices in dierent
time segments. You are
advised to set the peak
power to a low value when
the electricity price is high.
● A maximum of 14 time
segments are allowed.
-
End dete
Peak power (kW) [0.000, 1000.000]
SUN2000-(3KTL-10KTL)-M1 Series
User Manual 7 Man-Machine Interaction