EasyManuals Logo

Huawei SUN2000 M0 Series User Manual

Huawei SUN2000 M0 Series
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #112 background imageLoading...
Page #112 background image
IPS Test Type Description External Signal
Setting
Local Command
Setting
S2 The level 1
overfrequency
protection threshold is
51.5 Hz and the level
1 underfrequency
protection threshold is
47.5 Hz.
Step 3 Tap Start to start the IPS test. After the IPS test is complete, IPS State is displayed
as IPS state success. Tap Reports in the upper right corner of the IPS test screen
to view IPS Self-Check Report.
----End
SUN2000-(3KTL-10KTL)-M0
User Manual F IPS Test (for Italy CEI0-21 Grid Code only)
Issue 06 (2020-10-23) Copyright © Huawei Technologies Co., Ltd. 105

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000 M0 Series and is the answer not in the manual?

Huawei SUN2000 M0 Series Specifications

General IconGeneral
Rated AC Output Power3000W
European Efficiency96.7%/97%/97%/97.3%/97.5%/97.8%
CommunicationRS485, Wi-Fi
Protection DegreeIP65
Weight17 kg
Dimensions440 x 650 x 220 mm
Max. efficiency98.6%
MPPT voltage range200-1000V
No. of MPPTs2
Operating temperature range-25°C to +60°C
Cooling methodNatural convection
Protection ratingIP65
AC output voltage230V