Figure 6-8 RS485 Settings
NO TE
The RS485 addresses of dierent inverters must be dierent.
----End
6.4 Powering O the System
Precautions
WARNING
After the SUN2000 is powered o, the remaining electricity and heat may still
cause electric shocks or body burns. Therefore, put on protective gloves and
operate the SUN2000
ve minutes after the power-o.
Procedure
Step 1 Send a shutdown command from the app.
Step 2 Turn
o the AC switch between the SUN2000 and the power grid.
Step 3 Set the DC SWITCH at the bottom of the SUN2000 to the OFF position.
Step 4 Turn
o the DC switch between the PV string and the SUN2000 if there is one.
----End
SUN2000-(3KTL-10KTL)-M0
User Manual 6 Commissioning
Issue 06 (2020-10-23) Copyright © Huawei Technologies Co., Ltd. 67

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000 M0 Series and is the answer not in the manual?

Huawei SUN2000 M0 Series Specifications

General IconGeneral
Rated AC Output Power3000W
European Efficiency96.7%/97%/97%/97.3%/97.5%/97.8%
CommunicationRS485, Wi-Fi
Protection DegreeIP65
Weight17 kg
Dimensions440 x 650 x 220 mm
Max. efficiency98.6%
MPPT voltage range200-1000V
No. of MPPTs2
Operating temperature range-25°C to +60°C
Cooling methodNatural convection
Protection ratingIP65
AC output voltage230V

Related product manuals