EasyManua.ls Logo

Huawei SUN2000 M0 Series - 6 Commissioning; Check before Power-On

Huawei SUN2000 M0 Series
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Commissioning
6.1 Check Before Power-On
Table 6-1 Installation checklist
No.
Check Item Acceptance Criteria
1 SUN2000 installation The SUN2000 is installed correctly, securely, and
reliably.
2 Smart Dongle The Smart Dongle is installed correctly and
securely.
3 Cable layout Cables are routed properly as required by the
customer.
4 Cable tie Cable ties are secured evenly and no burr exists.
5 Grounding The ground cable is connected correctly,
securely, and reliably.
6 Turn o the switches The DC SWITCH and all the switches connected
to the SUN2000 are set to OFF.
7 Cable connections The AC output power cable and DC input power
cable are connected correctly, securely, and
reliably.
8 Unused terminals and ports Unused terminals and ports are locked by
watertight caps.
9 Installation environment The installation space is proper, and the
installation environment is clean and tidy,
without foreign matter.
SUN2000-(3KTL-10KTL)-M0
User Manual 6 Commissioning
Issue 06 (2020-10-23) Copyright © Huawei Technologies Co., Ltd. 55

Table of Contents

Related product manuals