Basic Programming and Setup
PROGRAM RULES
Program Rules customizes each program for special purposes.
IGNORE CALENDAR DAYS OFF
Check the box if the program should be allowed to run on
Calendar Days O that apply to other programs.
NO WATER WINDOW START AND END
Enter start and end times for the portion of the day during
which automatic irrigation is never allowed. Program will
never be allowed to run during this period, although Manual
operations will be allowed. If a program is suspended by a No
Water Window, it will be logged as an alarm, for corrective
action.
STATION DELAY DELAY BETWEEN STATIONS
Sets an interval between each station in a program. This can
be used for slow-closing valves, recharging pressure tanks,
etc. During the delay, the P/MV output will continue running
for 15 seconds, unless this is adjusted in the Devices, P/MV
Operation screen.
CALENDAR DAYS OFF
Create a list of dates on which the whole controller will not be
allowed to run, regardless of Water Day settings. Programs
that have been set to Ignore Calendar Days O in the Program
Rules screen will be allowed to run anyway.
PROGRAM SUMMARY
Once a program has start times, run times, and water days, it
will run automatically without further setup. To see how the
program is congured, select Program Summary from the
Programming screen.
The Summary will show the total number of Programs ready
to run for the entire controller.
Press the Programs so key to view details for each program.
Press the Graph so key to view a chart of all programs
occurring over time. Turn the dial to view the graph up to 7
days in advance.
Non-Water Windows and Calendar Days O options will show
on the graph in red as Water Restrictions, meaning automatic
irrigation cannot occur during those periods.