27
Flow Menu
Flow Menu
The ow menu includes all setup for the various ow
functions. These are described in detail in the Flow Operations
section on page 34.
CLEAR FLOW ALARMS
The Clear Flow Alarm function enables a MainSafe or Flow
Zone that has had an Overow alarm to water again.
If the Alarm Clear Delay is set to Manual Only, a user must
manually clear the alarm with this function before it can water
again.
If Alarm Clear Delay is set to a time in HH:MM format, the
controller can run irrigation in the MainSafe or Flow Zone
automatically again, aer the time has elapsed.
Settings Menu
TIME/DATE
This function sets time and date. See the Basic Programming
section on page 13.
REGIONAL SETTINGS
This function sets regional preferences. See the Basic
Programming section on page 13.