EasyManua.ls Logo

Hunter ACC2 - Station Logs; Filter Logs; Export Logs; Module Info

Hunter ACC2
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30 hunter.direct/ACC2help
Diagnostics Menu
STATION LOGS
Station logs record every event that occurs in the controller
(up to 1,500 events), beginning with the most recent. This can
be useful for advanced troubleshooting, or to verify that a
station actually watered.
FILTER LOGS
This allows any of the three logs to be ltered by date, or by
record number.
EXPORT LOGS
CLIK SENSOR DIAGNOSTICS
Sensor: This shows each sensor and same.
State: This shows the current status of the sensor.
- Inactive means the sensor is normal.
- Active means the sensor is currently alarmed.
- Delayed means the sensor was recently alarmed, and is
now inactive, but a Rain Delay is in eect for the sensor.
- Disabled means the check box for the sensor (Devices
menu) is unchecked, and no responses will be caused by
the sensor.
In Use?: This shows whether the sensor is currently in use
at the Sensor Response menu to shut down any programs.
MODULE INFO
Select Module Info to see current version of all rmware in
all modules in the controller. Modules that are empty or not
reporting are shown as Not Present.
So keys allow shortcuts to other diagnostic checks, which
are also available directly from the Diagnostics menu.
When the facepack is reversed in the frame, it will
automatically go to the Module Info screen. The facepack
is still fully operational, and pressing the Home button can
access all programming functions when the facepack is
reversed. The controller will still run automatically if the
facepack is le reversed.
All logs can be written to the SD card. This function
is described in more detail in the Advanced Features
section on page 32.