CAUTION: Movements of the
reference station will affect the
correction data sent to the product with
the accurate position. The reference
station must be installed tightly on the
post or wall.
CAUTION: If the reference station is
moved after the installation of the work
area, the work area must be deleted
and installed again. The work area on
the map moves if the reference station
moves.
WARNING: Obey national regulations
about electrical safety.
WARNING: The product is only to be
used with the power supply unit
supplied by Husqvarna.
WARNING: Do not put the power
supply at a position where there is a
risk that it can become wet. Do not put
the power supply on the ground.
WARNING: Do not encapsulate the
power supply. Condensed water can
harm the power supply and increase
the risk of electrical shock.
WARNING: Risk of Electric Shock.
Install only to an residual-current
device (RCD) when connecting the
power supply to the wall socket.
Applicable to USA/Canada. If power
supply is installed outdoors: Risk of
Electric Shock. Install only to a
covered Class A GFCI receptacle
(RCD) that has an enclosure that is
weatherproof with the attachment plug
cap inserted or removed.
WARNING: The power supply cable
and extension cable must be outside
the work area to avoid damage to the
cables.
When connecting the power supply, only use a
power outlet that is connected to an residual
current device (RCD).
3.6.4.1 To install the reference station on a post
1. Attach the post tightly to a wall, roof top or
the ground. Make sure that the post does
not move.
2. Pull the cable on the reference station
through the slot in the arm.
3. Attach the connector to the clips on the arm.
4. Install the screw (Torx 20) on the arm of the
reference station.
24
- Installation
1460 - 002 - 06.04.2020