CAUTION: If the low-voltage
cable is not attached tightly with
cable ties it can be damaged in
hard wind.
10. Put the power supply at a minimum height of
30 cm / 12 in. from the ground.
11. Connect the power supply cable to a
100-240V power outlet.
12. Make sure that the LED status indicator on
the reference station is solid green. Refer to
LED indicator lamp on the reference station
on page 55
.
3.6.4.2 To install the reference station on a wall
Note: As wall materials vary, screws for fixing to
the wall are not included.
1. Hold the arm for the reference station on the
wall where you will attach it. Make 4 marks
on the wall where you will attach 4 screws.
Note: If the reference station is installed on a
wall the top of the reference station must be
above the wall.
2. Drill 4 holes in the wall for the 4 screws.
3. Install the reference station on the wall with
4 screws.
4. Put the cable of the reference station
through the slot in the arm.
5. Attach the connector to the clips on the arm.
26
- Installation
1460 - 002 - 06.04.2020