English-72
REPAIR INSTRUCTIONS
Emptying the particle trap
Compress so that the rubber tabs open and
any particles can drop out.
Cleaning the cyclone filter
Remove the cover (52) held in position by
two brace locks and clean the inside of the
cover. Wash with soap water and blow dry
using compressed air after removing the
cover.
Replacing the Air Filter
Remove the cover held by two brace locks.
Pull the air filter cartridge (51) straight out
and remove it.
Wipe the inside of the air filter housing dry. If
necessary, dampen the cloth with white spirit
or fuel. Water or compressed air must not be
used.
Install a new air filter cartridge with the hole
inwards and press into position. It is impor-
tant that the particle trap is turned straight
down when installing the cover.
8009-788
Particle trap on air filter
8009-789
Cyclone filter
IMPORTANT INFORMATION
It is important that the particle trap is turned
straight down when installing the cover.
8009-790
Air filter cartridge
IMPORTANT INFORMATION
Do not used compressed air to clean the filter.
Do not wash the paper filter.
Do not oil the paper filter.

Table of Contents