The distance’s maximum when servo motor searching the Grid signal:
EX
The servo motor of X-axis turns 3/4 round = 5.000 mm MCM216 = 5.200
The servo motor of Y-axis turns 3/4 round = 5.000 mm MCM217 = 5.200
If it exceeds the range and the motor can not find the Grid still. ERR15 will be
shown up.
Setting by engineer.
18. HOME Limit Format (Default = 0)
Valu e = 0 The signal type is Normally Close.
Valu e = 1 The signal type is Normally Open.
19. OT Limit Format (Default = 0)
Valu e = 0 The signal type is Normally Close.
Valu e = 1 The signal type is Normally Open.
20. D-axis adjust value Format□□□□.□□□ (Default = 0.000)
EX 1.
MOPM = 326.00
Measure the distance of machine opening = 327.319
D-axis adjust value= 1.319
EX 2.
MOPM = 326.00
Measure the distance of machine opening = 325.117
D-axis adjust value= -0.883
21. Y-Opening default setting Format□□□□.□□□ (Default = 0.000)
Fig 54