HUST CNC H6D-B3 MANUAL
41
The distance’s maximum when servo motor searching the Grid signal:
EX
:
The servo motor of X-axis turns 3/4 round = 5.000 mm MCM216 = 5.200
The servo motor of Y-axis turns 3/4 round = 5.000 mm MCM217 = 5.200
※ If it exceeds the range and the motor can not find the Grid still. ERR15 will be
shown up.
Setting by engineer.※
18. HOME Limit Format:□ (Default = 0)
Valu e = 0 ; The signal type is 『Normally Close』.
Valu e = 1 ; The signal type is 『Normally Open』.
19. OT Limit Format:□ (Default = 0)
Valu e = 0 ; The signal type is 『Normally Close』.
Valu e = 1 ; The signal type is 『Normally Open』.
20. D-axis adjust value Format:□□□□.□□□ (Default = 0.000)
EX 1.
MOPM = 326.00
Measure the distance of machine opening = 327.319
『D-axis adjust value』= 1.319
EX 2.
MOPM = 326.00
Measure the distance of machine opening = 325.117
『D-axis adjust value』= -0.883
21. Y-Opening default setting Format:□□□□.□□□ (Default = 0.000)
Fig 54