42
22. D-axis HOME Limit setting Format:□□□□.□□□ (Default = 0.000)
Show the coordinate when finish the HOME operation
23. R-axis HOME Limit setting Format:□□□□.□□□ (Default = 0.000)
Measure the distance when finish the HOME operation
Fig 55
24. G00 Linear accel / decel Format:□□□ (Default = 100)
Unit: millisecond
Setting Range: 4 ~ 512 millisecond.
25. MPG direction Format:□ (Default = 0)
Adjust the MPG direction (Positive or Negative to the Axis)
According to the bit, bit 0 represents X-axis, bit 1= Y-axis, and bit 2=Z-axis.
EX1: When tending to change the MPG direction of Y-axis, its setting is 2
EX2: When tending to change the MPG direction of X-axis and Y-axis, it’s
setting is 3.
26. MPG Accel / Decel time Format:□□□ (Default = 64)
Unit: milliseconds
Setting Range: 4~512 ms.
The motor acceleration / deceleration time is equal to MCM #236 when MPG
hand-wheel is used in JOG mode.
27. 0 = Metric mode, 1 = Inch mode Format:□ (Default = 0)
Setting = 0, Measurement in METRIC unit.
Setting = 1, Measurement in INCH unit.
Setting by engineer.※
28. Language 0 = Chinese, 1 = English Format:□ (Default = 0)
29. Basic parameter cipher code 1 Format:□□□□ (Default = 0)
+ I017
I010
- I018
The value setting