EasyManua.ls Logo

HUST CNC H6D-B3 - Page 48

Default Icon
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HUST CNC H6D-B3 MANUAL
42
22. D-axis HOME Limit setting Format□□□□.□□□ (Default = 0.000)
Show the coordinate when finish the HOME operation
23. R-axis HOME Limit setting Format□□□□.□□□ (Default = 0.000)
Measure the distance when finish the HOME operation
Fig 55
24. G00 Linear accel / decel Format□□□ (Default = 100)
Unit: millisecond
Setting Range: 4 ~ 512 millisecond.
25. MPG direction Format (Default = 0)
Adjust the MPG direction (Positive or Negative to the Axis)
According to the bit, bit 0 represents X-axis, bit 1= Y-axis, and bit 2=Z-axis.
EX1: When tending to change the MPG direction of Y-axis, its setting is 2
EX2: When tending to change the MPG direction of X-axis and Y-axis, it’s
setting is 3.
26. MPG Accel / Decel time Format□□□ (Default = 64)
Unit: milliseconds
Setting Range: 4~512 ms.
The motor acceleration / deceleration time is equal to MCM #236 when MPG
hand-wheel is used in JOG mode.
27. 0 = Metric mode, 1 = Inch mode Format (Default = 0)
Setting = 0, Measurement in METRIC unit.
Setting = 1, Measurement in INCH unit.
Setting by engineer.
28. Language 0 = Chinese, 1 = English Format (Default = 0)
29. Basic parameter cipher code 1 Format□□□□ (Default = 0)
+ I017
I010
- I018
The value setting