HUST CNC H6D-B3 MANUAL
43
30. Basic parameter cipher code 2 Format:□□□□ (Default = 0)
If the password setting of MCM is zero, user can get in the displaying page
directly.
If it is not zero, user must enter the correct password to get in the MCM page.
Until the password has been solved, the『Correct』function under JOG mode will
not be set-up.
31. Parameter list 0 = NO, 1 = YES Format:□
※ Setting by engineer.
32. Lock the function key on the MCM page Format:□
The value = 0, Lock
The value = 1, Unlock
value = 1, illustration is below:
Fig 56
Y SET 0: Clean the machine coordinate when press this key 6 sec.
CLR_ALL: Press this key 6 sec
Clean the memory of the FLASH ROM and set the default to
original value.
B_MCM: Burn MCM parameters into FLASH-ROM when press this key 2
sec.
B_VAR: Burn variables into FLASH-ROM when press this key 2 sec.
(#9000-#9999)
CLR_P: Delete all programs.
LD VAR: Read variables burned into FLASH-ROM when press this key 2
sec. (#9000-#9999)
LD MCM: MCM parameters reset when press this key 2 sec.