HUST CNC H6D-B3 MANUAL
43
30. Basic parameter cipher code 2 Format□□□□ (Default = 0)
If the password setting of MCM is zero, user can get in the displaying page
directly.
If it is not zero, user must enter the correct password to get in the MCM page.
Until the password has been solved, theCorrectfunction under JOG mode will
not be set-up.
31. Parameter list 0 = NO, 1 = YES Format
Setting by engineer.
32. Lock the function key on the MCM page Format
The value = 0, Lock
The value = 1, Unlock
value = 1, illustration is below
Fig 56
Y SET 0 Clean the machine coordinate when press this key 6 sec.
CLR_ALL Press this key 6 sec
Clean the memory of the FLASH ROM and set the default to
original value.
B_MCM Burn MCM parameters into FLASH-ROM when press this key 2
sec.
B_VAR Burn variables into FLASH-ROM when press this key 2 sec.
(#9000-9999)
CLR_P Delete all programs.
LD VAR Read variables burned into FLASH-ROM when press this key 2
sec. (#9000-9999)
LD MCM MCM parameters reset when press this key 2 sec.