HUST CNC H6D-B3 MANUAL
50
MCM
No.
Factory
Default
Setting
Unit Description
Setting
BIT4 = 0 , B axis find Home grid available,
= 1 , no need to find.
BIT5 = 0 , C axis find Home grid available,
= 1 , no need to find.
BIT6 = 0 , U axis find Home grid available,
= 1 , no need to find.
BIT7 = 0 , V axis find Home grid available,
= 1 , no need to find.
BIT8 = 0 , W axis find Home grid available,
= 1 , no need to find.
504
100 msec
G00 Linear accel./decel. Time, 4~512 ms
505
100 msec
G01 Linear accel./decel. Time, 10~1024 ms
506
100 msec
Accel/Decel time when in G99 mode (mm/rev)
507
100 msec
Time Setting for spindle acceleration
508
0
System Reserved
509
4096 pulse
Spindle encoder resolution (pulse/rev)
510
3000 rpm
Max. spindle rpm at 10 volts
511 0 v Spindle voltage command zero drift correction (open circuit)
512 0
Spindle voltage command acce/dece slope correction (open
circuit)
513 0 rpm Spindle RPM correction (based on feedback from the encoder)
514
0
Start number for program block number generation
515
0
Increment for program block number generation
516
1
Denominator of feed-rate when in MPG test mode
517
1
Numerator of feed-rate when in MPG test mode
518 0
MPG direction
519
64 ms
Set Acceleration/Deceleration Time for MPG (4~512)
520
38400
RS232 Baud rate, 38400, 19200 / EVEN /2 Bit
521 0
Setting whether R000~R99 data in PLC are stored when power
is cut off. 0=NO, 256=YES
522
0 pulse
Servo Error Counter
523 0
Radius/Diameter Programming mode
524
0
0=Metric mode, 25400=inch mode mcm541=0,1
525
3
Error in Circular Cutting, ideal value=1
526 0
Pulse settings
0: pulse + direction 1: +/- pulse 2: A/B phase
527 1000 Setting G01 speed value at booting
528 0 Setting tool compensation direction =1 FAUNC, =0 HUST
529 0
It is used for adjusting the G01’s acceleration/deceleration time
when the acceleration/deceleration type is set to an “S” curve.
When MCM 5022, the function can then be sustained.
530 0
G31 input motion stop at hardware
531 0
Format setting
=0 standard,
=1 the system will automatically add a decimal point to even
numbers,
=2 line editing,
=4 automatically added with a decimal point in programming
532
2.000 mm
Mill modeSetting the backlash of G83
533 4096 pulse Setting the following error count for testing
534
Testing the function of axial setting of the servo following
errorbit0-X..
535 Controller ID number
536
Minimum slope setting of the Auto Teach function (with use of
C040)