HUST CNC H6D-B3 MANUAL
50
MCM
No.
Factory
Default
Setting
Unit Description
Setting
BIT4 = 0 , B axis find Home grid available,
= 1 , no need to find.
BIT5 = 0 , C axis find Home grid available,
= 1 , no need to find.
BIT6 = 0 , U axis find Home grid available,
= 1 , no need to find.
BIT7 = 0 , V axis find Home grid available,
= 1 , no need to find.
BIT8 = 0 , W axis find Home grid available,
= 1 , no need to find.
504
100 msec
G00 Linear accel./decel. Time, 4~512 ms
505
100 msec
G01 Linear accel./decel. Time, 10~1024 ms
506
100 msec
Accel/Decel time when in G99 mode (mm/rev)
507
100 msec
Time Setting for spindle acceleration
508
0
System Reserved!
509
4096 pulse
Spindle encoder resolution (pulse/rev)
510
3000 rpm
Max. spindle rpm at 10 volts
511 0 v Spindle voltage command zero drift correction (open circuit)
512 0
Spindle voltage command acce/dece slope correction (open
circuit)
513 0 rpm Spindle RPM correction (based on feedback from the encoder)
514
0
Start number for program block number generation
515
0
Increment for program block number generation
516
1
Denominator of feed-rate when in MPG test mode
517
1
Numerator of feed-rate when in MPG test mode
518 0
MPG direction
519
64 ms
Set Acceleration/Deceleration Time for MPG (4~512)
520
38400
RS232 Baud rate, 38400, 19200 / EVEN /2 Bit
521 0
Setting whether R000~R99 data in PLC are stored when power
is cut off. 0=NO, 256=YES
522
0 pulse
Servo Error Counter
523 0
Radius/Diameter Programming mode
524
0
0=Metric mode, 25400=inch mode mcm541=0,1
525
3
Error in Circular Cutting, ideal value=1
526 0
Pulse settings
0: pulse + direction 1: +/- pulse 2: A/B phase
527 1000 Setting G01 speed value at booting
528 0 Setting tool compensation direction =1 FAUNC, =0 HUST
529 0
It is used for adjusting the G01’s acceleration/deceleration time
when the acceleration/deceleration type is set to an “S” curve.
When MCM 502=2, the function can then be sustained.
530 0
G31 input motion stop at hardware
531 0
Format setting
=0 standard,
=1 the system will automatically add a decimal point to even
numbers,
=2 line editing,
=4 automatically added with a decimal point in programming
532
2.000 mm
Mill mode;Setting the backlash of G83
533 4096 pulse Setting the following error count for testing
534
Testing the function of axial setting of the servo following
error(bit0-X..)
535 Controller ID number
536
Minimum slope setting of the Auto Teach function (with use of
C040)