5 Starting up
CAUTION:
Before commissioning select the type of fluid to be measured (default setting: Oil),
procedure see chap. 9.2.
NOTE:
After recognizing a valid measurement value, the ENS 3000 (version with 4 switch
points), checks for diversion points within the active zone beyond the recognized
measuring value. These will be corrected immediately. After approx. 15 minutes,
the corrections will be stored permantently, but only if the set fluid to be measured
is oil.
Menu point
is used to reset faulty corrections and the learning phase re-starts
(see Chapter 9.2 Summary of the basic settings).
Method of determining the offset value:
We suggest the following procedure for determining the value of the fluid level offset:
¾ Installation resp. mounting of ENS 3000 inside the tank
¾ Check: is the display flashing or does it show a value greater than zero.
¾ If the display flashes, the level lies outside the active measuring zone (level too
high, resp. level too low).
If the system reports low level, the fluid level will gradually be filled up by until 0 is
displayed. Then, the ENS 3000 is removed from the tank and the fluid level inside
the tank is determined by a measuring unit. Depending on the model, this value is
displayed in the menu in " inch " or " cm " after having been determined.
¾ If the display shows value 0 or if high level is reported, the level is gradually
reduced by draining the fluid until the value 0 appears in the display. After removing
the ENS 3000 from the tank the process is as described above.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HYDACELECTRONIC ENS 3000 and is the answer not in the manual?

HYDACELECTRONIC ENS 3000 Specifications

General IconGeneral
BrandHYDACELECTRONIC
ModelENS 3000
CategorySwitch
LanguageEnglish