9 Basic settings
The function of the ENS 3000 can be adapted to suit the particular application by altering
several basic settings. These settings are combined in a single menu.
9.1 CHANGING THE BASIC SETTINGS
NOTE:
• When the menu is activated, no switching operations are carried out!
Activating the Basic Settings menu:
To close the Basic Settings menu:
Select the "END" menu item, set to "YES": the ENS 3000 returns to normal display mode
after 2 s.
NOTE:
• If there is no activity in this menu for approx. 25 seconds, the menu will
automatically close and any changes you have made will not be applied.
press the "
mode
" key and
hold it down.
Switch on the supply volltage
(hold key down until "
MEnu
"
appears in the display)
use the
and
keys to
change the setting, and then
select the next menu item.
Display
(release the
"
mode
" key)
press "
mode
" key until the
required parameter
appears. Then release the
key. (Overview, see 9.2)
→