Status 21.08.2015 HYDAC ELECTRONIC GMBH Part No. 669850
15 Order details
ENS 3 X 1 X – X –XXXX – 000 – K
Serial-no.
(determined by manufacturer)
Temperature sensor
1 =with temperature sensor
2 =without temperature sensor
Only possible with output options "2", "3" and "5"
Mechanical connection
1 =22 mm diameter collar to fit
cuttting ring coupling G22L
Electrical connection
6 = M12x1, 4 pole
only possible with output options “2“ und “3“
(connector not supplied)
8 = M12x1, 5 pole
only possible with output options “5“
(connector not supplied)
P = M12x1, 8 pole
only possible with output options “8“
(connector not supplied)
Output
2 =2 switching outputs
(in conjunction with electrical connector type “6“ only)
3 =1 switching output and 1 analogue output
(in conjunction with electrical connector type “6“ only)
5 =2 switching outputs and 1 analogue output
(in conjunction with electrical connector type “8“ only)
8 =4 switching outputs and 2 analogue outputs
(in conjunction with electrical connector type “P“ only)
Probe length
0100 = 9.80 inch, 0162 = 16.20 inch
0205 = 20.50 inch, 0287 = 28.70 inch
Modification number
400 = US-standard (determined by manufacturer)
Material of probe
K =ceramic