WeatherTRAK 2-Wire Controller Installation Guide
22
©
2020 HydroPoint Data Systems Inc. All rights reserved. 800.362.8774 • hydropoint.com
Press * to assign the decoder. A similar screen displays, confirming a successful assignment:
Setup: 15 10:43am
PROGRAMMING SUCCESSFUL
Device ID: NO01 (Orange)
(Remember to label)
_____ _____
Label the decoder then unplug it from the Station Program terminal.
To assign the next decoder, press . To exit, press .
Configuring the decoder to the POC
Press Flow.
Press until the SELECT FLOW OPTION screen displays.
Press + or to select Points of Connections.
Press . Make sure the POC is undelined. If it is not, press
Press to go toP the flow menu.
Press + or to select the correct POC.
Reassigning a Decoder
In the case where you have to reassign a decoder, simply disconnect the decoder in question and plug it
into the Station Program terminal then repeat the decoder assigning process described above.