11
CONNECT HYDRAULIC HOSES
The tool and power pack are connected by a 10,000 PSI
operating pressure (40,000 PSI burst) twin-line hose
assembly. Each end of the hose has both a male and a
female connector (the male coupler is inserted into the
female). NOTE: An odd number of hoses is required to
extend the hydraulic hose length.
• IMPORTANT: Make sure system is depressurized
before connecting or disconnecting hoses.
• Make sure that all hydraulic hoses are rated for 10,000
PSI Operating Pressure.
• Remove protective caps from couplings and inspect
couplings for dirt and debris.
• Connect supply hose to male coupling “A”.
Connect return hose to female coupling “R”
• To avoid tool malfunction. do not reverse coupler
orientation.
• If daisy chaining hoses, use an odd number of hoses
to preserve coupler orientation.
• Protect pump couplings with caps and plugs when
not in use, to avoid damage and contamination.
B
A
QUICKCONNECT COUPLERS PUSHPULL
To connect hoses with quick-connect couplers, insert male end into female end and push until it snaps in place. Twist
locking ring so that ball (A) does NOT align with slot (B) to prevent accidental uncoupling. To disconnect, align ball (A)
with slot (B) and pull back locking sleeve.
IMPORTANT: Always make sure system is depressurized before disconnecting hoses.
Male
Female