Chapter 1 RCON-LC System
1.5 Specifications
1-11 ME0416-1A
1.5 Specifications
1.5.1 General specifications
The specifications regarding installation conditions are listed below.
Item Specifications
Ambient operating
temperature
0 to 55°C (0 to 40degC for Simple Absolute Unit and SCON-CB)
Ambient operating
humidity
5%RH to 85%RH (There should be no water condensation or freeze)
Ambient storage
temperature
20 to 70°C
Operating
atmosphere
Avoid corrosive gas and in particular avoid excessive dust
Altitude 1,000m or less
Vibration
resistance
Frequency: 10~57 Hz/Amplitude: 0.075mm, Frequency: 57~150 Hz/
Acceleration: 9.8m/s2
XYZ directions Sweep time: 10 minutes Number of sweeps: 10 times
Shock resistance Drop height: 800mm 1 corner, 3 edges, 6 faces
Overvoltage
category
I
Electric shock
protection
mechanism
24V System : Class III
200V System : Class I
Pollution degree II
Degree of
protection
IP20
Insulation
withstanding
voltage
DC500V 10M(between power supply terminal and frame grounding)
Cooling method Natural air cooling and forced air cooling by fan unit