39
Return Key: [Field, New Line]
When the Return Key =New Line, the functions specified in the New Line
parameter are performed. When the Return Key = Field, the functions
specified in the New Line parameter are performed unless the target line is
within a protected field. The cursor will then move to the first character
position of the next unprotected field.
Enter Key: [Send, Return]
The Enter Key can be defined to be either a Send or Return Key.
New Line: [<CR>, <CR><LF>]
This parameter specifies the codes generated when the return key is pressed.
Send Key: [Page, Line]
The contents of the current page is sent to the host when the Send Key is
pressed and Send Key is selected for page. The Contents of the current line
is sent to the host when the Send Key is pressed and Send Key is selected for
line.
Insert Character: [Mode, Space]
♦ Mode – enters insert mode when the insert key is pressed.
♦ Space – a space character is inserted at the current cursor position when
the insert key is pressed.
Local Leadin: [On, Off]
This parameter is only available when Key Mode (in the Kybd menu) is
ScanCode. If Local Leadin is off, the only local function, shown in Appendix A,
that is available is Ctrl-Scroll Lock to enter Setup. If Local Leadin is on, the Setup
keystroke “introduces” the keystroke as local and then local functions can be
generated using the keystrokes listed in Appendix A. For example, to enter
Setup when ScanCode and Local Leadin are on, press Ctrl-Scroll Lock to
introduce this as a local function (“LEAD” will appear in the status line), and
then Ctrl-Scroll Lock to enter Setup.
Local Leadin will not work if Comm Mode is set to Half Block
or Full Block.