EasyManua.ls Logo

IBM NeXtScale System - Page 223

IBM NeXtScale System
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7. Hardware management 205
Table 7-6 Power redundancy IPMI commands
Table 7-7 Acoustic mode IPMI commands
Description NetFn CMD Data
Get PSU policy 0x32 0xa2 Request Data:
None
Response Data:
Byte 1: Completion code (0x00)
Byte 2: PSU Policy
򐂰 0: No redundancy
򐂰 1: N+1
򐂰 2: N+N
Byte 3: Oversubscription mode (0: disable; 1: enable)
Byte 4: Power bank LSB
Byte 5: Power bank MSB
Set PSU policy 0x32 0xa3 Request Data:
Byte 1: PSU Policy
򐂰 0: No redundancy
򐂰 1: N+1
򐂰 2: N+N
Response Data:
Byte 1: Completion code (0x00) or out of range (0xC9) or config not
allowed (0x01) or bank lack (0x02)
Set Over
Subscription
mode
0x32 0x9c Request Data:
Byte 1: Over Subscription mode
򐂰 0: Disable
򐂰 1: Enable
Response Data:
Byte 1: Completion code (0x00) or cur not supported (0x5d) or
param out of range (0xc9)
Description NetFn CMD Data
Set Acoustic
mode
0x32 0x9b Request Data:
Byte 1: Acoustic mode (0x00: disable; 0x01: mode1 - 28%; 0x02;
mode2 - 34%; 0x3 mode3 - 40%)
Response Data:
Byte 1: Completion code (0x00) or out of range (0xC9)

Table of Contents

Related product manuals