Table 28. ssss-102 through ssss-640 SRNs (continued)
SRN FFC Description and action
ssss-122 ssss A SCSD reservation conflict error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-124 ssss A SCSD check condition error occurred.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-126 ssss 252B A software error was caused by a hardware failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-128 252B ssss
software
The error log analysis indicates a hardware failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-129 252B ssss
software
Error log analysis indicates a SCSD bus problem.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-130 ssss Error log analysis indicates a problem reported by the disk drive's self-monitoring
function.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-132 ssss A disk drive hardware error occurred.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
Chapter 2. Diagnostics 179

Table of Contents

Other manuals for IBM Power PS700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power PS700 and is the answer not in the manual?

IBM Power PS700 Specifications

General IconGeneral
BrandIBM
ModelPower PS700
CategoryServer
LanguageEnglish

Related product manuals