Table 28. ssss-102 through ssss-640 SRNs (continued)
SRN FFC Description and action
ssss-134 252B
software
The adapter failed to configure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-135 ssss 252B
software
The device failed to configure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-136 ssss The certify operation failed.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-137 ssss 252B Unit attention condition has occurred on the Send Diagnostic command.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-138 ssss Error log analysis indicates that the disk drive is operating at a higher than
recommended temperature.
1. Make sure that:
v The ventilation holes in the blade server bezel are not blocked.
v The management-module event log is not reporting any system environmental
warnings.
2. If the problem remains, call IBM support.
ssss-140 199 252B
ssss
Error log analysis indicates poor signal quality.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-640 ssss Error log analysis indicates a path error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
180 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)