Look for the rightmost 4 characters (yyyy in 6xxxyyyy) in the error code; this is the reference code. Find
the reference code in Table 8.
Table 8. 6xxxyyyy SRCs
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
6xxxyyyy
Error Codes
Description Action
632Byyyy codes are Network File System (NFS) virtual optical SRCs
632BCFC1 A virtual optical device cannot
access the file containing the
list of volumes.
On this partition and on the Network File System server, verify
that the proper file is specified and that the proper authority is
granted.
632BCFC2 A non-recoverable error was
detected while reading the list
of volumes.
Resolve any errors on the Network File System server.
632BCFC3 The data in the list of volumes
is not valid.
On the Network File System server, verify that the proper file is
specified, that all files are entered correctly, that there are no blank
lines, and that the character set used is valid.
632BCFC4 A virtual optical device cannot
access the file containing the
specified optical volume.
On the Network File System server, verify that the proper file is
specified in the list of volumes, and that the proper authority is
granted.
632BCFC5 A non-recoverable error was
detected while reading a
virtual optical volume.
Resolve any errors on the Network File System server.
632BCFC6 The file specified does not
contain data that can be
processed as a virtual optical
volume.
On the Network File System server, verify that all the files specified
in the list of optical volumes are correct.
632BCFC7 A virtual optical device
detected an error reported by
the Network File System
server that cannot be
recovered.
Resolve any errors on the Network File System server.
632BCFC8 A virtual optical device
encountered a non-recoverable
error.
Install any available operating system updates.
632Cyyyy codes are virtual optical SRCs
632CC000 Informational system log entry
only.
No corrective action is required.
632CC002 self configuring SCSI device
(SCSD) selection or reselection
timeout occurred.
Refer to the hosting partition for problem analysis.
632CC010 Undefined sense key returned
by device.
Refer to the hosting partition for problem analysis.
632CC020 Configuration error. Refer to the hosting partition for problem analysis.
632CC100 SCSD bus error occurred. Refer to the hosting partition for problem analysis.
632CC110 SCSD command timeout
occurred.
Refer to the hosting partition for problem analysis.
632CC210 Informational system log entry
only.
No corrective action is required.
22 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)

Table of Contents

Other manuals for IBM Power PS700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power PS700 and is the answer not in the manual?

IBM Power PS700 Specifications

General IconGeneral
BrandIBM
ModelPower PS700
CategoryServer
LanguageEnglish

Related product manuals