Table 15. B700xxxx Licensed internal code SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes Description Action
6907 System bus error
1. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
2. Go to “Isolating firmware problems” on
page 218.
6908 System bus error Replace the system-board and chassis
assembly, as described in “Replacing the FRU
system-board and chassis assembly” on page
260.
6909 System bus error
1. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
2. Go to “Isolating firmware problems” on
page 218.
6911 Platform LIC unable to find or retrieve
VPD LID file.
Check for server firmware updates; then,
install the updates if available.
6912 Platform LIC unable to find or retrieve
VPD LID file.
Check for server firmware updates; then,
install the updates if available.
6944 Informational system log entry only. No corrective action is required.
6950 A platform dump has occurred.
1. Collect the platform dump information.
2. Go to “Isolating firmware problems” on
page 218.
6951 An error occurred because a partition
needed more NVRAM than was
available.
Use the Integrated Virtualization Manager
(IVM) or management console to delete one or
more partitions.
6952 Informational system log entry only. No corrective action is required.
6953 PHYP NVRAM is unavailable after a
service processor reset and reload.
Go to “Isolating firmware problems” on page
218.
6954 Informational system log entry only. No corrective action is required.
6955 Informational system log entry only. No corrective action is required.
6956 An NVRAM failure was detected. Go to “Isolating firmware problems” on page
218.
6965 Informational system log entry only. No corrective action is required.
6970 PCI host bridge failure
1. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
2. If the problem persists, use the “PCI
expansion card (PIOCARD) problem
isolation procedure” on page 194 to
determine the failing component.