Table 15. Declared noise emissions for 5U SAS expansion enclosures in accordance with ISO 9296
Model and type Declared A-Weighted Sound Power
Level, L
WAd
(B)
Declared A-Weighted Sound Pressure
Level, L
pAm
(dB)
Operating Idling Operating Idling
Fully congured 5U
expansion enclosure
( 2072-92F or 2072-
E92)
8.5 8.5 85 85
Notes:
1. Declared level L
WAd
is the upper-limit A-weighted sound power level. Declared level L
pAm
is the mean A-
weighted sound pressure level that is measured at the 1-meter bystander positions.
2. All measurements are made in conformance with ISO 7779 and declared in conformance with ISO 9296.
3. "B" and "dB" are abbreviations for bels and decibels. 1 B = 10 dB.
Important: Government regulations (such as those prescribed by OSHA or European Community Directives)
might govern noise level exposure in the workplace and might apply to you and your server installation. This
system is available with an optional acoustical door feature that can help reduce the noise that is emitted from
this system. The actual sound pressure levels in your installation depend upon a variety of factors, including
the number of racks in the installation; the size, materials, and conguration of the room where you designate
the racks to be installed; the noise levels from other equipment; the room ambient temperature, and
employees' location in relation to the equipment. Further, compliance with such government regulations also
depends upon a variety of additional factors, including the duration of employees' exposure and whether
employees wear hearing protection. IBM recommends that you consult with qualied experts in this eld to
determine whether you are in compliance with the applicable regulations.
Shock and vibration specications
Table 16 on page 11 provides the shock testing results for each Storwize V5000E system.
Table 16. Shock testing
specications
Shock categories Test level Performance
Operational 5 g 10 ms 1/2 Sine <=25 g 10 ms
Non-operational 30 g 10 ms 1/2 Sine <=75 g 11 ms
Table 17 on page 11 provides the vibration testing results for Storwize V5000E systems.
Table 17. Vibration testing
specications
Vibration categories Test level Performance
Operational 0.21 grms 5 - 500 Hz Random Throughput loss <= 10% FCAL <=
0.68 grms
Non-operational 1.04 grms 2 - 200 Hz Random <=3.12 grms
Shipping 0.3 g 2 - 200 Hz Sine <= 5 g
Rotational vibration Normal operation performance
measurements in enclosure with
no external vibration.
Throughput loss for all drives of the
same type within performance
prole.
Support rail specications
Table 18 on page 12 provides the supported depth of the rack for each Storwize V5000E system.