Table 4. Abbreviated list of POST error codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v See the parts listing in the Problem Determination and Service Guide to determine
which components are customer replaceable units (CRU) and which components
are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must
be performed only by a trained service technician.
Error code Description Action
5962 IDE DVD drive configuration error.
1. Run the Configuration/Setup
Utility program and load the
default settings (see “Starting
the Configuration/Setup Utility
program” on page 44).
2. Reseat the following
components:
a. DVD drive cable
b. DVD drive
c. System board
3.
Replace the components listed
in step 2 one at a time, in the
order shown, restarting the
server each time.
8603 Pointing-device error.
1. Reseat the pointing device.
2. Replace the following
components one at a time, in
the order shown, restarting the
server each time:
a. Pointing device
b. (Trained service technician
only) System board
00012000 Processor machine check error.
1. (Trained service technician
only) Reseat the
microprocessor.
2. Replace the following
components one at a time, in
the order shown, restarting the
server each time:
a. (Trained service technician
only) Microprocessor
b. (Trained service technician
only) System board
Chapter 5. Solving problems 57