Results
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 106.
Installing a hot-swap fan assembly
Use this information to install a hot-swap fan assembly.
About this task
The server comes standard with five dual-motor hot-swap cooling fans.
Attention: To ensure proper operation, replace a failed hot-swap fan within 30
seconds.
To install an additional hot-swap fan, complete the following steps:
Procedure
1. Read the safety information that begins on “Safety” on page v and “Installation
guidelines” on page 43.
2. Remove the cover (see “Removing the cover” on page 51).
3. Touch the static-protective package that contains the new fan to any unpainted
metal surface on the server. Then, remove the new fan from the package.
Figure 51. ServeRAID M5000 advanced feature key installation
80 IBM System x3550 M3 Type 4254 and 7944: Installation and User's Guide