battery pack. If the charge indicator still does not turn on,
replace the battery pack.
Checking the Battery Pack
1. Power off the computer.
2. Remove the battery pack and measure the voltage
between battery terminals 1 (+) and 4 (−). See the
following figure.
Note: Signal lines not used in these steps are used
for communication between the system and
the battery.
3. If the voltage is less than +11.0 V dc, the battery pack
has been discharged. Recharge the battery pack.
If the voltage is still less than +11.0 V dc after
recharging, replace the battery.
Note: If the voltage of the battery pack is 0 V, it is
not defective.
4. If the voltage is more than +11.0 V dc, measure the
resistance between battery terminals 3 and 4. The
resistance must be 4 to 30 K ohm.
If the resistance is not correct, replace the battery
pack.
If the resistance is correct, replace the subcard.
Terminal Voltage (V dc) / Signal
1 +0 to +13.5
2 N/C
3 Thermal
4 Ground (−)
5 Select
6 A-Ground
ThinkPad 380, 385 (2635) 35

Table of Contents

Other manuals for IBM THINKPAD S05L-1270-01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM THINKPAD S05L-1270-01 and is the answer not in the manual?

IBM THINKPAD S05L-1270-01 Specifications

General IconGeneral
BrandIBM
ModelTHINKPAD S05L-1270-01
CategoryLaptop
LanguageEnglish

Related product manuals