EasyManua.ls Logo

Icom IC-M506 - MB-75;MB-132 Installation

Icom IC-M506
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
105
12
CONNECTIONS AND MAINTENANCE
MB-75/MB-132 installation
An optional MB-75/MB-132 f l u s h m o u n t Kit is available for
mounting the transceiver to a flat surface such as an instru-
ment panel.
KEEP the transceiver and microphone at least 1 meter
(3.3 feet) away from the vessel’s magnetic navigation com-
pass.
Using the template on page 112, carefully cut a hole into q
the instrument panel, or wherever you plan to mount the
transceiver.
Slide the transceiver through the hole, as shown below. w
D MB-75 installation
Attach the 2 supplied bolts (M5 q × 8 mm) on either side of
the transceiver.
Attach the clamps on either side of the transceiver. w
•Make sure that the clamps align parallel to the transceiver’s
body.
w
w
Clamp
Supplied bolt
Tighten the end bolts on the clamps (rotate clockwise) so e
that the clamps press firmly against the inside of the in-
strument control panel. (Torque: 0.6 Nm)
Tighten the locking nuts (rotate counterclockwise) so that r
the transceiver is securely mounted in position as below.
Connect the antenna and power cable, then return the in- t
strument control panel to its original place.

Table of Contents