EasyManua.ls Logo

Icom ID-31A - Page 61

Icom ID-31A
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
52
8
TROUBLESHOOTING
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
PROBLEM POSSIBLE CAUSE SOLUTION REF.
After your call, the repeater
does not transmit a reply.
•Therepeatersettingiswrong.
•Thetransceiverisoutoftherepeaterrange,or
your transmission does not reach the repeater.
•Setthecorrectrepeater.
•Correcttherepeaterfrequency,frequencyoffset,or
duplexsetting.
•Trytoaccessanotherrepeater.
Advanced
Instruction
Section 3
After your call, the repeater
replies UR?’ and its call
sign.
•Thecallwassuccessfullysent,butnostation’s
signal was immediately received.
•Waitforawhile,andtryitagain.
After your call, the repeater
replies‘RX’ or‘RPT?’and
the call sign of its gateway
repeater.
•MYcallsignhasnotbeenset.
•Your callsign hasnotbeenregisteredtothe
D-STAR Server. Or it’s wrong.
•Yourcallingstationcallsignhasnotbeenregis-
tered to the D-STAR Server. Or it’s wrong.
•SettheMYcallsign.
•RegisteryourcallsigntotheD-STARServer.Orcon-
firm the registration of your call sign.
•Asktheserver’sadministratoraboutyourcallingsta-
tion’s call sign.
After your call, the repeater
replies‘RPT?’andcallsign
of the called repeater.
•TheD-STARcannotconnecttothecalledre-
peater, or it’s busy.
•
Wait for a while, and try it again.
After your call, the repeater
repliesRPT?’ and its call
sign.
•Thecallsignofthecalledrepeateriswrong. •Correctlysetthecalledrepeatercallsign.
Even holding down ,
the
DR mode will not appear.
•Therepeaterlisthasbeencleared. •ReprogramtherepeaterlistusingtheCS-31clon-
ing software.
•Reprogramtherepeaterlistwiththetransceiver.
Even holding down ,
the
received call sign will not
set to the operating call
sign
•Thecallsignhasnotbeencorrectlyreceived. •Tryitagain,afterthetransceiverhasagainreceived
its call sign.
The repeater does not ac-
cept your gateway call.
Your call sign has not been registered to the D-
STAR system
Ask your desired repeater’s administrator about call
sign registration.
While operating D-STAR

Table of Contents