INSTALLATION AND CONNECTIONS
Wiring the EX-2780 system cable
CAUTION: NEVER cut the supplied system cable.
q Loosen the four bolts on the bottom of the scanner
unit body using the supplied allen wrench (q), and
open the top cover. (w)
w
Loosen the sealing nut on the scanner unit and pass
the system cable through the sealing nut and sealing
tube. (e)
e Connect the power cable (black and red) connec-
tor to the power unit connector through the looped
cable tie. (r)
r Insert the PA cable (black and white) connector into
the PA unit connector. Be sure to follow the diagram
below carefully. (t)
Secure the looped PA cable with the looped cable tie.
(y)
t Connect the shielded cable ground wire to the chas-
sis with the screw, as shown in the diagram. (u)
y Clamp the system cable with the cable clamp metal
fitting using a screw near the sealing connector.
(i)
Be sure to clamp it tightly.
u Clamp the system cable with the ferrite EMI filter at-
tached near the sealing connector. (o)
Be sure to clamp it tightly.
Secure the ferrite EMI filter with cable tie.
i Tighten the sealing-nut, then close the top cover.
DO NOT stretch the system cable too much, other-
wise a miss contact of the connector may occur.
o Tighten the four bolts on the bottom of the scanner
body. (Use a torque wrench to 9.8 N•m; 7.23 lbf•ft.)
Allen wrench
Scanner body
Fig. 1
q
w
Ferrite EMI filter
Cable tie
Cable clamp
i
o
Sealing tube
Sealing Nut
e
Fig. 2
Fig. 3
Shielded cable
ground wire
System cable
u
r
t
Looped
cable tie
Power cable
PA cable
y