FAULT FINDING
FAULT FINDING FAULT FINDING FAULT FINDING FAULT FINDING FAULT FINDING
Ideal Logic Code Combi - Installation and Servicing
84
ALTERNATING ‘F’ AND ‘2’ - FLAME LOSS
Does the boiler ignite for a short
time and then extinguish?



Check the detection electrode and
associated harness for: continuity,
visual condition and position (Refer to


Replace as necessary
NO
Check gas supply and
rectify fault
NO

Is 215Vdc supply available at the Gas



Check spark generator and associated
harness for: continuity and visual

functioning correctly?

NO
Check ignition electrode and associated harness

to Frame 54) Are these functioning correctly?

Check siphon and
condensate drain pipe
work for blockage and

now working OK?
Check wiring from gas

If the wiring is OK then

NO


NO
Replace Ignition
Electrode and
associated harness as
necessary
NO
Replace Gas Valve
* Note: due to the wave form of the rectied voltage, the reading will vary depending on the
type of meter used to measure the value. In general terms a reading greater than 150V
indicates that the correct voltage is supplied to the gas valve.
85
ALTERNATING ‘F’ AND ‘3’ - FAN FAULT

and has not deteriorated? Does the wiring have continuity?


Rectify Wiring &
connections
Is there 230Vac at Blue and Brown connections to the 3 way connection on the Fan?
NO

NO
Replace Fan
86
ALTERNATING ‘F’ AND ‘4’ - FLOW THERMISTOR FAULT


Check the resistance using a suitable multimeter

At 25
o
     

o
     

o
C expect 1,000 - 1,100 Ohms





NO
Check and replace wiring as necessary
NO

206279-1.indd 56 06/01/2011 09:10:49