LanTEK III 161809 Iss 2
User Manual Page36
5.4.1 Cable Name in Format TIA/EIA 606A
To determine cable name, a structure for the test portion is created. The three (3) cable
parameters 606A Drop, 606A Backbone and 606A Backbone Pair/Fiber are available.
1. Use Arrow keys to navigate to "Cable ID" and press Enter.
Fig. 34 Cable ID
5.4.2 Cable Parameter 606A Drop
Name of horizontal cable line (e.g. 1 building, 1 floor, 1 distribution, sockets)
1. Use soft key Drop to select cable parameter 606A Drop.
Fig. 35 Cable Parameter 606A Drop
AAA A - AA 0000
Floor Telecom room Panel Port
2. Use Left/Right Arrow Keys to navigate to desired position in port area. Use
Up/Down Arrow Keys
to assign characters and numbers.
3. Proceed in the same manner with positions Panel, Telecom Room and Floor.
4. Use soft key to hide individual positions. Assembling the cable line
automatically generates the 606A-Name.
5. Press Enter to save the cable name. Use Escape to exit menu without making
changes.