EasyManua.ls Logo

IDEAL Networks LanTEK III - Custom Cable Preferences and Cable Parameters

IDEAL Networks LanTEK III
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LanTEK III 161809 Iss 2
User Manual Page70
6.18.3 Custom Cable Parameters
Fig. 90 Custom Cable Parameters
Parameters Description
Frequency range
Use this menu to set the lowest and highest frequency for certification and
evaluation of cable performance.
Connector Pinout
Use this screen to determine the configuration of the contact pins of the plug.
Note:
Tests for NEXT, loss, capacitance, DC-resistance and impedance cannot be
performed on wire pairs that have not been selected.
Test Limits
Use this screen to adjust the pass/fail limits for the Autotest to your
requirements.
Link models
The custom limits for NEXT and loss are specified as constant limit or according
to the link models. The frequency limits depend on LanTEK
®
II model and link
type.
Select Autotests
Not all cable lines require the complete Autotest test series. Use this option to
select the individual Autotests to be performed.
Custom Name/NVP
Use Alphanumeric Keys to enter a custom name or edit the NVP value.
LanTEK
®
II Cable Tester can save up to 10 custom cable types.

Table of Contents

Other manuals for IDEAL Networks LanTEK III

Related product manuals