Page #310 background image
5: F
UNCTIONS
AND
S
ETTINGS
5-4 FC6A S
ERIES
MICROS
MART
U
SER
S
M
ANUAL
FC9Y-B1722
*1 Can be used only with the Plus CPU module.
*2 Can be used only with the All-in-One CPU module.
Input Configuration These settings configure special input functions such as the external input filter values and high-speed counters.
High-speed counter
Catch input
Interrupt input
Frequency measurement
Input filter
Analog voltage input
Analog input
Timer interrupt
Communication Ports These settings configure the FC6A Series MICROSmart communication ports that communicate with
external devices.
Maintenance communication
User communication
Modbus RTU master/slave
Data link master/slave station
J1939 (CAN J1939 All-in-One CPU module only)
External Memory
Devices
These settings configure the CSV file format and the maximum file size of the log data that is saved to
the SD memory card.
CSV file format
Data log and trace
*1
Device Settings Configure the order to store the upper and lower words for 32-bit data.
Program Protection Applies the protection to the user program by configuring a password so unauthorized users cannot
inadvertently upload or download it.
Self Diagnostic Configure the watchdog timer monitoring the operating status of the FC6A Series MICROSmart.
Calendar & Clock The FC6A Series MICROSmart is equipped with an internal clock and its calendar data (year, month,
day, day of the week) and clock data (hour, minute, second) can be used in user programs. Daylight
savings time can also be configured for the internal clock.
Network Settings
*2
These settings configure information for connecting the All-in-One CPU module to a network using Ethernet
port 1.
Network
Management
*2
These settings configure the FC6A Series MICROSmart's internal clock and the ping timeout time for
the PING instruction and when the auto ping function is being executed.
SNTP settings
Ping settings
Ethernet Port 1
*1
These settings configure information for connecting the Plus CPU module to a network using Ethernet
port 1. These settings are also used to configure SNTP settings for getting the time, the ping timeout
duration when using the PING instruction or auto ping, the send e-mail settings, web server settings,
and FTP client/server settings.
IP settings
DNS settings
SNTP settings
Ping settings
E-mail settings
Web server settings
FTP client settings
FTP server settings
Ethernet Port 2
*1
These settings configure information for connecting the Plus CPU module to a network using Ethernet
port 2. These settings are also used to configure the ping timeout duration when using the PING
instruction or auto ping.
IP settings
DNS settings
Ping settings
Connection Settings These settings configure server/client communication used in FC6A Series MICROSmart Ethernet
communication.
Maintenance communication server
User communication server/client
User communication (UDP)
*1
Modbus TCP communication server/client

Table of Contents

Other manuals for IDEC MICROSmart FC6A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC MICROSmart FC6A Series and is the answer not in the manual?

IDEC MICROSmart FC6A Series Specifications

General IconGeneral
BrandIDEC
ModelMICROSmart FC6A Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals