5.1.8 > Anti-tamper / anti-pulling switches
Please refer also to “Tamper Switch” section.
These switches are activated as soon as there is enough pressure applied on the terminal against the
wall. They are deactivated as soon as this pressure is not big enough, e.g. when the terminal is pulled out
of the wall.
When the switches are deactivated, the MorphoWave Compact terminal acts as required by the related
configuration key (see MorphoWave Compact Administrator / User Guide for key configuration
description):
Ignore the event (default): useful during normal maintenance operations.
Send an alarm message to the Central Access Controller, through the usual channel of the access
control result messages (Wiegand, DataClock, RS485, Ethernet or Wi-Fi™). An alarm switch (relay
contact) is directly available on block terminal «tamper switch pins». Please refer to “Wiring overview”
and to “Tamper Switch” sections.
Generate an audible alarm signal with the speaker and an alert message on the screen.