6.2.14. PAPDU_FELICA_REQ_SERVICE
This command issues a REQ SERVICE as defined in JIS 9.6.2. P1. On receiving this command an NFC
Forum tag type 3 will respond with the area key version of the specified area and the service key
version of the specified service.
Command APDU:
Service Code List /
Area Code List
8 bytes IDm + No. of Service or areas(n) + Service version
or area version list (2*n)
6.2.15. PAPDU_FELICA_REQ_RESPONSE
This command issues a REQ RESPONSE as defined in JIS 9.6.1. When an NFC Forum tag type 3 receives
this command, it responds with its current mode (0/1/2).
Command APDU:
6.2.16. PAPDU_FELICA_READ_BLK
This command issues a READ as defined in JIS 9.6.3
● P1 specifies the number of service
● P2 specifies the number of blocks
● Data buffer specifies the service code and block list
When an NFC Forum tag type 3 receives this command, it responds with the record value of the
specified service.
Command APDU:
Service
Code List,
Block List
8 bytes IDm + Status Flag 1 + Status Flag 2 + No.