EasyManua.ls Logo

Identiv uTrust 4711F - Contact_Read_Insertion_Counter

Identiv uTrust 4711F
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document Version 1.2
Last revised on
2017-09-26
Page 84 of 92
Reference Manual for uTrust 4701F and uTrust 4711F Readers
Output:
For Get/Set guard time, the output will be the Character/Block Guard Time value.
Byte0
Byte1
Byte2
Byte3
Character Guard time in ETU
BIT31-BIT24
BIT23-BIT16
BIT15-BIT8
BIT7-BIT0
DataIn = 82 00 01
DataOut: 00 00 00 18 (4 bytes)
6.3.5.14. CONTACT_READ_INSERTION_COUNTER
This Escape command is supported through the READER_GENERIC_ESCAPE command and retrieves
the number of times a contact smart card has been inserted into the reader.
Input:
The first five bytes of the input buffer follow APDU structure as per [PCSC3-AMD1]. The 6
th
byte is the
Escape code 0x00 to identify the command.
Byte0
Byte1
Byte2
Byte3
Byte4
Byte5
Le
0xFF
0x70
0x04
0xE6
0x01
0x00 (Escape
code)
4 (Insertion counter is a 4
byte value)
Output:
Byte0
Byte1
Byte2
Byte3
Byte4
Byte5
Insertion counter value
SW1
SW2
BIT31-BIT24
BIT23-BIT16
BIT15-BIT8
BIT7-BIT0
0x90
0x00
In case of any error, only SW1 and SW2 set with error status will be returned.