Dozer Fine Tuning
After having thoroughly validated each calibration procedure (booms, then bucket, then 2D
and then laser in many positions), a depth difference may persist between the teeth of the
bucket and the dozer blade relative to the ground.
To remove this difference, follow the recommended procedure:
• Set L1 to zero.
• Enable Dozer mode.
• Configure the laser by using the bucket procedure: put the bucket on a surveyor
stake and set the depth to zero, then catch the laser.
• Continue the initialization process of the dozer (no slope).
• Move your excavator and put the blade on the surveyor stake and adjust your
dipperstick to catch the laser again.
• The depth on the blade is the value L1 that you must enter into the Machine
Parameters of Dozer.