Installation Procedures Dozer Calibration
74
Dozer Fine Tuning
After having thoroughly validated each calibration procedure (booms, then bucket, then 2D
and then laser in many positions), a depth difference may persist between the teeth of the
bucket and the dozer blade relative to the ground.
To remove this difference, follow the recommended procedure:
Set L1 to zero.
Enable Dozer mode.
Configure the laser by using the bucket procedure: put the bucket on a surveyor
stake and set the depth to zero, then catch the laser.
Continue the initialization process of the dozer (no slope).
Move your excavator and put the blade on the surveyor stake and adjust your
dipperstick to catch the laser again.
The depth on the blade is the value L1 that you must enter into the Machine
Parameters of Dozer.