80
Checking the System Accuracy
Laser Receiver Calibration Check – Method 1
• Setup a rotating laser approximately 5 feet (1.5 m) high with no slope.
• Lock the center tooth on the main working screen by taping on the center tooth on the bucket symbol on the left hand side of the screen.
• Mark a spot at a point to be reached by the machine.
• Place a grade rod on the spot and place your hand held detector on grade.
• Read on the grade rod the height difference of the reference spot to the rotating laser (Instrument HI).
• Initiate a first laser catch.
• Enter the height difference (HI) as the laser height and confirm.
• Perform a laser catch.
• Place the bucket center tip/edge on the marked spot on the ground. Your reading on the screen should be on grade. ± 1/3 inch (1 cm) is
acceptable.
• Check the laser receiver accuracy in various dipper stick angles.