Checking the System Accuracy
Laser Receiver Calibration Check Method 2
Setup a rotating laser approximately 5 feet (1.5 m) high with no slope.
Lock the center tooth on the main working screen by taping on the center tooth on the bucket symbol on the left hand side of the screen.
Mark a spot at a point to be reached by the machine.
Place the bucket center tip/edge on the marked spot on the ground.
Initiate a first laser catch.
Enter “0” as the bucket height and confirm.
Perform a laser catch.
Place a grade rod on the spot and place your hand held detector on grade.
Read the grade rod and determine the height difference between that spot and the rotating laser beam.
The measured laser height difference should match the calculated laser height (red number) shown on the screen. ± 1/3 inch (1 cm) is
acceptable.
Check the laser receiver accuracy in various dipper stick angles.