EasyManuals Logo

IDS 816 Installer Manual

IDS 816
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
IDS 816 700-283-02I Issued September 2009
24
LOCATION 38 Global Options
LED
ON / OFF
Action
1
ON
A user assigned to any partition may cancel the siren
OFF
Only a user assigned to the partition that triggered the siren may cancel
the siren
2
ON
Enables keypad trouble beep
OFF
Disables keypad trouble beep
3
ON
Enables telephone line monitoring
OFF
Disables telephone line monitoring
4
ON
Enables use of programmable loop response time
OFF
Standard 100ms loop response time
5
ON
Enables keypad beep on communication
OFF
Disables keypad beep on communication
6
ON
Enables keypad fire, medical and panic keys
OFF
Disables keypad fire, medical and panic keys
7
ON
Enables the display of bypassed and stay zones when armed in the stay
mode
OFF
Disables the display of bypassed and stay zones when armed in the stay
mode
8
ON
Enables the siren delay
OFF
Disables the siren delay
9
ON
Enables zone doubling
OFF
Disables zone doubling (expansion / keypad zones can be used to
expand the system to sixteen zones.)
10
ON
Enable box tamper
OFF
Disable box tamper
11
ON
Enable siren tamper
OFF
Disable siren tamper
12
ON
Enable 485 device tamper
OFF
Disable 485 device tamper
13
ON
Dedicated panic zone – silent
OFF
Dedicated panic zone – audible
Default values are shaded

Table of Contents

Other manuals for IDS 816

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDS 816 and is the answer not in the manual?

IDS 816 Specifications

General IconGeneral
BrandIDS
Model816
CategoryKeypad
LanguageEnglish

Related product manuals