IDS 816 700-283-02I Issued September 2009
34
11. Communicator Options
LOCATION 110 Communication Delay
Value
Delay
0 3 seconds
1 10 seconds
2 15 seconds
3 20 seconds
4 25 seconds
5
30 seconds
6
45 seconds
7 1 minute
8 2 minutes
9 3 minutes
10 4 minutes
11 5 minutes
12 10 minutes
13 15 minutes
14 18 minutes
15 21 minutes
If delayed communications is enabled for either partition, (locations 128 and 129) the panel will wait for
this period before reporting zone violations and restorals. If the alarm is cancelled within this time zone,
violations and restorals will not be reported. Violations will however be logged in the event log. Panic
events will be reported instantly regardless of any selected delay period.
LOCATION 111
Reporting Options
LED
On / Off
Action
1
ON Tone dialling enabled
OFF Pulse dialling enabled
2
ON Join the telephone numbers together
OFF Keep two separate telephone numbers
3
ON Enable dual reporting
OFF Disable dual reporting
Single reporting options (LED 3 off)
4
ON
Reports to secondary number only after failing on
attempting the primary number.
(Panic event initiates dual reporting)
OFF
Alternates reporting attempts between both
numbers until successful with one of them.
(Single reporting, regardless of panic)
Default values are shaded