IDS X-Series Training v2.7 | Standard User Functions
89
Buzz Zone
A buzz zone is only active during stay arms. It is a zone that when violated, when the system is stay armed,
will buzz the keypad for 30 seconds before sounding the alarm.
How to setup buzz zones.
Explanation
Key Presses
Press and hold the [4] buzz zone key until the beep
[4]
Enter each zone to be a buzz zone until complete for zones 1 to
16
[1] [*] [2] [*] [8] [*]
To access zones 17 to 32 press the [*] key
[*]
Now zone 17 is represented by zone 1, 18 by 2, 19 by zone 3,
etc.
[1] [*] [5] [*] [1] [0] [*] [1] [5] [*]
To access the next 16 zones press the [*] key, and add the
zones as needed
[*]
When complete press the [#] key
[#]
Chime Zone
A chime zone is a zone that will beep all keypads 5 times when a zone is violated in the unarmed state.
How to create chime zones:
Bypassing Zones
If a zone is faulty and is preventing the system from being armed it can be bypassed. If option 14 in location
14 is enabled you must enter a user code to bypass zones.
Explanation
Key Presses
Press and hold the [9] bypass key until the beep
[9]
Enter a [USER CODE] followed by the [*] key
[1] [2] [3] [4] [*]
Enter each zone to be bypassed until complete for zones 1 to 16
[4] [*] [6] [*] [1] [1] [*]
To access zones 17 to 32 press the [*] key
[*]
Now zone 17 is represented by zone 1, 18 by 2, 19 by zone 3, etc.
[1] [3] [*] [1] [4] [*] [1] [6] [*]
To access the next 16 zones press the [*] key, and add the zones as
needed
[*]
When complete press the [#] key
[#]
The zone LED will be on
Panic zones can be bypassed if enabled in zone options location 101 to 164
Explanation
Key Presses
Press and hold the [2] chime zone key until the beep
[2]
Enter each zone to be a chime zone until complete for zones 1 to 16
[4] [*] [6] [*] [1] [1] [*]
To access zones 17 to 32 press the [*] key
[*]
Now zone 17 is represented by zone 1, 18 by 2, 19 by zone 3, etc.
[1] [3] [*] [1] [4] [*] [1] [6] [*]
To access the next 16 zones press the [*] key, and add the zones as
needed
[*]
When complete press the [#] key
[#]

Table of Contents

Other manuals for IDS X Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDS X Series and is the answer not in the manual?

IDS X Series Specifications

General IconGeneral
Key TypeTactile
BacklightYes
Operating Voltage12VDC
Weight150g
Operating Temperature-10°C to +55°C

Related product manuals