8.4.11 dAP ─ damping
Damping of the measured analogue value�
Setting also influences the set point, the IO-Link process data and the display
Value: 0�000���4�000 s (T value: 63 %)�
At 0�000 damping is not active�
8.5 Parameters via IO-Link
The following functions or parameters are only available via IO-Link tools�
8.5.1 C.uni – customer-specific unit
Customer-specific unit with max� 4 characters�
8.5.2 S.Loc – software locking
Value: ON/OFF
The device is locked for local menu settings�
Unlocking only via IO-Link�
8.5.3 Application-specific tag
Customer-specific application description, max� 32 characters long�
Value: “ *** ” / can be freely defined by the customer
8.5.4 Reset [Hi] and [Lo] memory
Reset of both memories: [Hi] and [Lo]�