30
Change from menu level 1 to menu level 2:
Press [Mode/Enter] until [EF] is
displayed.
 
Briefly press [Set]�
> The first parameter of the submenu is
displayed (here: [res])�
 
Locking / unlocking
The unit can be locked electronically to prevent unintentional settings�
Make sure that the unit is in the
normal operating mode�
Press [Mode/Enter] + [Set] for 10 s�
> [Loc] is displayed�
 

During operation: > [Loc] is briefly displayed if you try to change parameter values�
For unlocking:
Press [Mode/Enter] + [Set] for 10 s�
> [uLoc] is displayed�
 

On delivery: not locked�
Timeout:
If no button is pressed for 15 s during parameter setting, the unit returns to the
operating mode with unchanged values�