Parameter setting10
During parameter setting the unit remains in the operating mode internally� It
continues its monitoring function with the existing parameters until the parameter
setting has been completed�
General parameter setting10.1
3 steps must be taken for each parameter setting:
1
Selection of the parameter
Press [Mode/Enter] until the re- ►
quested parameter is displayed�.
2
Setting of the parameter value
Press [SET] and keep it pressed� ►
Current setting value of the param- >
eter flashes for 5 s�
After 5 s: setting value is changed: >
incrementally by pressing the button
once or continuously by keeping the
button pressed�
Numerical values are incremented continuously� For reducing the value: let the dis-
play move to the maximum setting value� Then the cycle starts again at the minimum
setting value�
3
Acknowledgement of the parameter
value
Press [Mode/Enter] briefly� ►
The parameter is displayed again� >
The new setting value is stored�
Setting of other parameters:
Start again with step 1� ►
Finishing the parameter setting:
Press [Mode/Enter] several times until the current measured value is displayed or wait ►
for 15 s�
The unit returns to the operating mode� >